ADT3100 Suspended solids/ TSS/ MLSS meter

General Information

Suspended Solids Meter based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of suspended solids and sludge concentration. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of cuspended colids and cludge concentration value. According to the usage environment, self-cleaning function can be equipped with.

Characteristics

Range: 0.1 ~ 20000 mg/L; 0.1 ~ 45000 mg/L; 0.1 ~ 120000 mg/L

Resolution: Less than ± 5% of the measured value

Pressure range: ≤0.4MPa

Power supply: AC220V±10%; 50Hz/60Hz

SPECIFICATION

Product
Suspended Solids (Sludge Concentration/ TSS/ MLSS) meter
Model
ADT3100
Main materials
lower casing: Aluminum with powder covering
cover: PA66+GF25+FR
Waterproof rate
IP65
Storage temperature
-20~70℃
Operation Temperature
-15~60℃
Output
three-way analog output 4-20mA, response parameters and corresponding scope can be programmed Note: the maximum load is 500 ohms
Relay
three-way relay can be set up, and response parameters and response values can be programmed
Display
128 * 64 dot matrix LCD with LED backlight
Digital Communication
MODBUS RS485 communication function, which can transmit real-time measurements
Power Supply
AC:85-500V, 50/60HZ, 5W
DC:9-36V
Size
145*125*162mm L*W*H
Weight
1.35 KG